483 research outputs found

    Estimation of elastic and viscous properties of the left ventricle based on annulus plane harmonic behavior

    Get PDF
    Assessment of left ventricular (LV) function with an emphasis on contractility has been a challenge in cardiac mechanics during the recent decades. The LV function is usually described by the LV pressurevolume (P-V) diagram. The standard P-V diagrams are easy to interpret but difficult to obtain and require invasive instrumentation for measuring the corresponding volume and pressure data. In the present study, we introduce a technique that can estimate the viscoelastic properties of the LV based on harmonic behavior of the ventricular chamber and it can be applied non-invasively as well. The estimation technique is based on modeling the actual long axis displacement of the mitral annulus plane toward the cardiac base as a linear damped oscillator with time-varying coefficients. The time-varying parameters of the model were estimated by a standard Recursive Linear Least Squares (RLLS) technique. LV stiffness at end-systole and end diastole was in the range of 61.86-136.00 dyne/g.cm and 1.25-21.02 dyne/g.cm, respectively. The only input used in this model was the long axis displacement of the annulus plane, which can also be obtained non-invasively using tissue Doppler or MR imaging

    Assessment of myocardial injury after reperfused infarction by T1ρ cardiovascular magnetic resonance.

    Get PDF
    BackgroundThe evolution of T1ρ and of other endogenous contrast methods (T2, T1) in the first month after reperfused myocardial infarction (MI) is uncertain. We conducted a study of reperfused MI in pigs to serially monitor T1ρ, T2 and T1 relaxation, scar size and transmurality at 1 and 4 weeks post-MI.MethodsTen Yorkshire swine underwent 90 min of occlusion of the circumflex artery and reperfusion. T1ρ, T2 and native T1 maps and late gadolinium enhanced (LGE) cardiovascular magnetic resonance (CMR) data were collected at 1 week (n = 10) and 4 weeks (n = 5). Semi-automatic FWHM (full width half maximum) thresholding was used to assess scar size and transmurality and compared to histology. Relaxation times and contrast-to-noise ratio were compared in healthy and remote myocardium at 1 and 4 weeks. Linear regression and Bland-Altman was performed to compare infarct size and transmurality.ResultsRelaxation time differences between infarcted and remote myocardial tissue were ∆T1 (infarct-remote) = 421.3 ± 108.8 (1 week) and 480.0 ± 33.2 ms (4 week), ∆T1ρ = 68.1 ± 11.6 and 74.3 ± 14.2, and ∆T2 = 51.0 ± 10.1 and 59.2 ± 11.4 ms. Contrast-to-noise ratio was CNRT1 = 7.0 ± 3.5 (1 week) and 6.9 ± 2.4 (4 week), CNRT1ρ = 12.0 ± 6.2 and 12.3 ± 3.2, and CNRT2 = 8.0 ± 3.6 and 10.3 ± 5.8. Infarct size was not significantly different for T1ρ, T1 and T2 compared to LGE (p = 0.14) and significantly decreased from 1 to 4 weeks (p < 0.01). Individual infarct size changes were ∆T1ρ = -3.8%, ∆T1 = -3.5% and ∆LGE = -2.8% from 1 - 4 weeks, but there was no observed change in infarct size for T2 or histologically.ConclusionsT1ρ was highly correlated with alterations left ventricle (LV) pathology at 1 and 4 weeks post-MI and therefore it may be a useful method endogenous contrast imaging of infarction

    Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging

    Get PDF
    Background: The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian-Eulerian framework. Results: The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. Conclusions: The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics

    Quantifying Acute Myocardial Injury Using Ratiometric Fluorometry

    Get PDF
    Early reperfusion is the best therapy for myocardial infarction (MI). Effectiveness, however, varies significantly between patients and has implications for long-term prognosis and treatment. A technique to assess the extent of myocardial salvage after reperfusion therapy would allow for high-risk patients to be identified in the early post-MI period. Mitochondrial dysfunction is associated with cell death following myocardial reperfusion and can be quantified by fluorometry. Therefore, we hypothesized that variations in the fluorescence of mitochondrial nicotinamide adenine dinucleotide (NADH) and flavoprotein (FP) can be used acutely to predict the degree of myocardial injury. Thirteen rabbits had coronary occlusion for 30 min followed by 3 h of reperfusion. To produce a spectrum of infarct sizes, six animals were infused cyclosporine A prior to ischemia. Using a specially designed fluorometric probe, NADH and FP fluorescence were measured in the ischemic area. Changes in NADH and FP fluorescence, as early as 15 min after reperfusion, correlated with postmortem assessment infarct size (r=0.695, p\u3c0.01). This correlation strengthened with time (r=0.827, p\u3c0.01 after 180 min). Clinical application of catheter-based myocardial fluorometry may provide a minimally invasive technique for assessing the early response to reperfusion therapy

    Fluorescence spectroscopy and imaging of myocardial apoptosis

    Get PDF
    Fluorometry is used to detect intrinsic flavoprotein (FP) and nicotinamide adenine dinucleotide NADH signals in an open-chest rabbit model of myocardial ischemia-reperfusion injury. Myocyte apoptosis has been shown clinically to contribute to infarct size following reperfusion of ischemic myocardium. A noninvasive means of assessing apoptosis in this setting would aid in the treatment of subsequent ventricular remodeling. We show that in vivo fluorometry can be useful in apoptosis detection in open-chest surgeries. Specific changes in myocardial redox states have been shown to indicate the presence of apoptosis. Two main mitochondrial intrinsic fluorophores, NADH and FP signals, were measured during normoxia, ischemia, and reperfusion experimental protocol. Ischemia was induced by occlusion of the largest branch of the circumflex coronary artery and fluorescence signals are collected by applying two different fluorescence techniques: in vivo fluorometry and postmortem cryoimaging. The first technique was employed to detect FP and NADH signals in vivo and the latter technique uses freeze trapping and lowtemperature fluorescence imaging. The heart is snap frozen while still in the chest cavity to make a snapshot of the metabolic state of the tissue. After freezing, the ischemic area and its surrounding border zone were excised and the sample was embedded in a frozen buffer for cryoscanning. These two data sets, in vivo fluorometry and low temperature redox scanning, show consistent extreme oxidation of the mitochondrial redox states (higher redox ratio) suggesting the initiation of apoptosis following reperfusion. This represents the first attempt to assess myocyte apoptosis in the beating heart

    Multimodal image analysis and subvalvular dynamics in ischemic mitral regurgitation

    Get PDF
    Background: The exact geometric pathogenesis of leaflet tethering in ischemic mitral regurgitation (IMR) and the relative contribution of each component of the mitral valve complex (MVC) remain largely unknown. In this study, we sought to further elucidate mitral valve (MV) leaflet remodeling and papillary muscle dynamics in an ovine model of IMR with magnetic resonance imaging (MRI) and 3-dimensional echocardiography (3DE). Methods: Multimodal imaging combining 3DE and MRI was used to analyze the MVC at baseline, 30 minutes post–myocardial infarction (MI), and 12 weeks post-MI in ovine IMR models. Advanced 3D imaging software was used to trace the MVC from each modality, and the tracings were verified against resected specimens. Results: 3DE MV remodeling was regionally heterogenous and observed primarily in the anterior leaflet, with significant increases in surface area, especially in A2 and A3. The posterior leaflet was significantly shortened in P2 and P3. Mean posteromedial papillary muscle (PMPM) volume was decreased from 1.9 ± 0.2 cm3 at baseline to 0.9 ± 0.3 cm3 at 12 weeks post-MI (P <.05). At 12 weeks post-MI, the PMPM was predominately displaced horizontally and outward along the intercommissural axis with minor apical displacement. The subvalvular contribution to tethering is a combination of unilateral movement, outward displacement, and degeneration of the PMPM. These findings have led to a proposed new framework for characterizing PMPM dynamics in IMR. Conclusions: This study provides new insights into the complex interrelated and regionally heterogenous valvular and subvalvular mechanisms involved in the geometric pathogenesis of IMR tethering

    In-vivo heterogeneous functional and residual strains in human aortic valve leaflets

    Get PDF
    Residual and physiological functional strains in soft tissues are known to play an important role in modulating organ stress distributions. Yet, no known comprehensive information on residual strains exist, or non-invasive techniques to quantify in-vivo deformations for the aortic valve (AV) leaflets. Herein we present a completely non-invasive approach for determining heterogeneous strains – both functional and residual – in semilunar valves and apply it to normal human AV leaflets. Transesophageal 3D echocardiographic (3DE) images of the AV were acquired from open-heart transplant patients, with each AV leaflet excised after heart explant and then imaged in a flattened configuration ex-vivo. Using an established spline parameterization of both 3DE segmentations and digitized ex-vivo images (Aggarwal et al., 2014), surface strains were calculated for deformation between the ex-vivo and three in-vivo configurations: fully open, just-coapted, and fully-loaded. Results indicated that leaflet area increased by an average of 20% from the ex-vivo to in-vivo open states, with a highly heterogeneous strain field. The increase in area from open to just-coapted state was the highest at an average of 25%, while that from just-coapted to fully-loaded remained almost unaltered. Going from the ex-vivo to in-vivo mid-systole configurations, the leaflet area near the basal attachment shrank slightly, whereas the free edge expanded by ~10%. This was accompanied by a 10° −20° shear along the circumferential-radial direction. Moreover, the principal stretches aligned approximately with the circumferential and radial directions for all cases, with the highest stretch being along the radial direction. Collectively, these results indicated that even though the AV did not support any measurable pressure gradient in the just-coapted state, the leaflets were significantly pre-strained with respect to the excised state. Furthermore, the collagen fibers of the leaflet were almost fully recruited in the just-coapted state, making the leaflet very stiff with marginal deformation under full pressure. Lastly, the deformation was always higher in the radial direction and lower along the circumferential one, the latter direction made stiffer by the preferential alignment of collagen fibers. These results provide significant insight into the distribution of residual strains and the in-vivo strains encountered during valve opening and closing in AV leaflets, and will form an important component of the tool that can evaluate valve׳s functional properties in a non-invasive manner
    corecore